Flow Ratings and Why They Matter

Flow Ratings and Why They Matter

Displacement vs FAD

  • Displacement: Theoretical output.
  • FAD (Free Air Delivery): Real usable air at ISO 1217 conditions. Always use FAD for sizing.

Sizing Your Compressor

Matching Tools to Capacity

Continuous-use tools need higher FAD and larger receivers; intermittent-use tools can rely on stored air. Add 20–30% margin for future needs.

Worked Examples

Paint booth: Spray gun needs 10 CFM → choose compressor with 15 CFM FAD.